The CoolTherm® platform provides heat exchangers with
10 kW to 35 kW within a closed cooling system (air-to-water)!
The PizzaPower® optimally distributes the required power
over the entire rack.

PizzaPower® – POWER DISTRIBUTION UNITS

New: 3-Phase DI-STRIP®

PizzaPowerA new generation of the power distribution units of
the DI-STRIP® range now ensures even more power:
PizzaPower® for fail-safe power supply distribution
in network racks.
Increasingly greater packing densities and therefore constantly increasing energy requirements in server
racks caused by Pizza Servers or 1 U rack servers
will now be handled electro technically:
Up to 35 kW dissipated heat can be removed from
modern CoolTherm® server racks. But how is the necessary power supplied into the rack, which
can cause such power losses?
The PizzaPower® (3x32 A) optimally distributes the
required power over the entire rack, with connection
of up to 21 consumers possible in the highest configuration level. 192 A can be supplied to the rack
with redundant feed via the PizzaPower®.


DI-STRIP® PizzaPower®

Strong Points

Cost-Effective
Simple and quick installation on the server rack’s
extrusion. Cost reduction in installation and wiring.
Supply
- Single-phase 32 A and three-phase 32 A.
- ≤22 kVA
- Ideal for implementing redundancy (e.g. 192 A).
Crystal Clear Assignment
Unmistakeable phase assignment
through colour-coding (L1, L2, L3).
Installation
Optimum distribution of Pizza
Center supply with simple installation
of power distribution unit (PDU).
Availability
Prevention of „Single Point of
Failure“ with individual fusing.
Certification



DI-STRIP® PizzaPower®
Technical data

- IEC 320 sockets (10 A).
- Individually fused via thermal circuit breaker
that can be reset in acc. with IEC600934.
- Cable: H05VV-F 5G 4 mm² (0,0062 in²)
- Cable: 4 m (13.1233 ft)
- With IEC60309 plug.
Material / Finish
Casing: Sheet steel, zinc passivated,
powder-coated
Dimensions
Height: Approx. 60 mm (2.3622")
Casing width: 84 mm (3.307")
Hight with cable: approx. 176 mm (6.9291")
Colour
Casing: RAL 9005, black
Approvals
CE label in accordance with low
potential guideline 73/23/EWG, EMC
guideline 89/336/EWG, GS Certificate,
CSA Certificate.
Load Rating
240/415 V, 1x 32 A, 3x 32 A,
Euro module 10 A
Supply Schedule
1 socket strip (PDU)
2 mounting brackets
1 19“ mounting bracket
1 operating instructions

 
   
 
   
Knürr AG  
   
Mariakirchener Straße 38
D-94424 Arnstorf
   
Telephone: +49 (0) 87 23-27 0
Fax: +49 (0) 87 23-27 154